• fireyeFireye放大模块70D41

    详细信息

     品牌:fireye  加工定制:否  型号:70D41  


    Fireye价格优惠! Fireye红外扫描仪,fireye 70D41控制器, Fireye control价格优惠!原装美国进口火焰检测器,Fireye紫外线扫描仪,Fireye Relay, Fireye module, Fireye紫外传感器,fireye价格,85UVF1-1QD价格,Fireye紫外传感器,Fireye火警报警仪, Fireeye 紫外,Fireeye火焰..Fireeye 燃烧控制器

     

    ---------------

    Fireye 70D41, For manually ignited burners, 230 VAC Burner Management Controls provide ignition and flame failure protection for manually started oil or gas

     

    产品介绍:

    70D40 Control and Cover
    72D1R1 Plug-in amplifier
    48PT2 Flame Scanner (specify cable length and mount)
    60-1386-2 Wiring Base
    Fireye D40-41 controls supersede similar Fireye C-Series controls and are directly plug-in replaceable.
    The following chart illustrates the comparison.
    Control 70D40 with Amplifier 72DUV1 will also replace a Fireye Type 25DU4 model 5040 provided
    the wiring is changed to the appropriate wiring shown later in this document.
    Note: When a C-Series unit is replaced with a D-Series unit, the chassis retaining clip (for a quarter
    turn fastener) in the wiring base must be replaced with a threaded clip that is supplied with each DSeries
    Control.
    A. Code 1 terminal load ratings all models: B. Terminal Load ratings for 70D40 Code 2 Models:
    Max. Rating of each external load terminal: TERMINAL MAXIMUM RATINGS
    125 VA PILOT DUTY TERMINAL 7 ONLY: Alternate
    Rating — 300 VA transformer
    and 130 VA pilot duty; and maximum
    combined load of not more
    than 3 motorized valves —
    Holding — 180 VA
    Opening— 635 VA
    Locked Rotor — 730 VA
    3, 5, 6, 8, X, A
    120 VAC 230 VAC 7
    Code 2
    or higher
    models only
    250 VA Pilot Duty or Motor rating as given below:
    5 amps 2.5 amps Voltage 120 VAC 230 VAC
    125 VA
    Pilot Duty
    125 VA
    Pilot Duty
    FULL LOAD 9.8 A 5.1 A
    LOCKED ROTOR 58.8 30.6 A
    C. CE Load ratings for 70D41
    TERMINAL MAXIMUM RATING AT 253 VAC
    3, 5, 6, 8, 13, D 1A RESISTIVE OR (cos ? = 1)
    7, A, M, P, X 4.5A RESISTIVE OR (cos ? = 1)
    D SERIES C SERIES
    OBSOLETE PART NUMBER COMPONENTS
    D40-5030 Control 70D40 - Amplifier 72D1R1 Type 26DF4 - Model 5030
    D41-5131 Control 70D41 - Amplifier 72D1R1T Type 26DF4 - Model 5131
    D40-5060 Control 70D40 - Amplifier 72DUV1 Type 25DU4 - Model 5060
    D41-5161 Control 70D41 - Amplifier 72DUV1T Type 25DU4 - Model 5161
    D40-5050 Control 70D40 - Amplifier 72DRT1 —
    D41-5151 Control 70D41 - Amplifier 72DRT1T —

    DESCRIPTION OF FIREYE SERIES D40-41 COMPONENTS
    Control Chassis and Cover Amplifier Flame Scanner
    Use with
    70D40 (120VAC) 50-60 Hz
    or
    70D41 (230VAC) 50/60 Hz
    Rectification
    72DRT1 2-4 sec. FFRT
    72DRT1T 1 sec. FFRT
    69ND1-1000K4
    69ND1-1000K6
    69ND1-1000K8
    1/2" mount 12" (300mm) flame rod.
    1/2" mount 18" (450mm) flame rod.
    1/2" mount 24" (600mm) flame rod.
    Infrared (IR) “Autocheck”
    72D1R1 2-4 sec. FFRT
    72D1R1T 1 sec. FFRT
    *72D1R3 2-4 Sec. FFRT
    *72D1R3T 1 Sec. FFRT
    * For specific applications see note
    below.
    48PT2-1003
    48PT2-9003
    48PT2-1007
    48PT2-9007
    1/2 straight mount 96" (2400mm) cable.
    1/2 angle mount 96" (2400mm) cable.
    1/2" straight mount 48" (1200mm) cable.
    1/2" angle mount 48" (1200mm) cable.
    Ultraviolet (UV)
    72DUV1 2-4 sec. FFRT
    72DUV1T 1 sec. FFRT
    UV8A
    UV1A3
    UV1A6
    UV2
    UV90-3, -6, -9
    45UV3-1050
    1/2" angle mount 72" (1800mm) wire (no cable).
    1/2" straight mount 36" (900mm) cable.
    1/2" straight mount 72" (1800mm) cable.
    3/8" straight mount 36" (900mm) cable.
    90º side opening, 36" (900mm), 72" (1800mm),
    or 108" (2700mm) cable.
    3/4" straight mount cast aluminum housing,
    72" (1800mm) wire (no cable).
    70D40 Only 72DUVS4 Repetitive Self-Check
    2-4 sec. FFRT
    72DUVS1T Repetitive Self-Check
    1 sec. FFRT
    45UV5-1009
    or
    45UV5-1008
    1" NPT mount 72" (1800mm) wire (no cable),
    120VAC shutter.
    or
    1" BSP mount 72" (1800mm) wire (no
    cable),120VAC shutter.
    70D40M Only Infrared (IR) AUTOCHECK
    72D1R3TM 1 sec. FFRT
    For special applications see Note
    below.
    48PT2-1003
    48PT2-9003
    48PT2-1007
    48PT2-9007
    1/2" straight mount 96" (2400mm) cable.
    1/2" angle mount 96" (2400mm) cable.
    1/2" straight mount 48" (1200mm) cable.
    1/2" angle mount 48" (1200mm) cable.
    70D41 Only 72DUVS1T or 72DUVS4 45UV5-1007 1" BSP mount 72" (1800mm) wire, no cable.
    230VAC shutter
    Wiring Base 60-1386-2 Standard base for surface mounting
    60-1466-2 Open base for cabinet mounting
    NOTE: Infrared “AUTOCHECK” amplifier modules 72D1R3, 72D1R3T, and 72D1R3T may be used for burner applications firing special
    fuel such as sawdust, sander dust, low BTU gas. The 72D1R3 type amplifiers are not to be used on any liquid fuel fired burner as it may
    result in malfunction causing damage to property and/or injury to personnel.
    ACCESSORIES / SPARE PARTS
    Part No. Description Used with Part No. Description Used with
    4-263-1 Firetron Cell 48PT2 60-801 1/2" Coupling w/Pyrex Window 48PT2
    4-314-1 UV Tube 45UV5, 45UV3 60-1199-1 1" NPT Coupling w/Quartz Window 45UV5-1009
    10-88 Set of 3 orifice plugs 48PT2 60-1199-2 1" BSP Coupling w/Quartz Window 45UV5-1009
    35-69 1/2" NPT Heat Insulator 48PT2-UV1 60-1257 1/2" Coupling w/Quartz Window UV1A
    35-127-1 1" NPT Heat Insulator 45UV5-1009 60-1290 1/2" Coupling w/Quartz Lens UV1A
    35-127-3 1" BSP Heat Insulator 45UV5-1007/8 60-1664-3 1" NPT Swivel Mounting Flange 45UV5-1009
    46-38 Quartz Lens 45UV5 60-1664-4 1" BSP Swivel Mounting Flange 45UV5-1007/8
    60-302 Swivel Mounting Flange 48PT2, UV1A 61-436 Lens Cap 48PT2